UTB prepared the permit and construction design for the extension of the Fegyvernek-Örményes municipal wastewater treatment plant under the KEOP programme, supplied the BIODEC™ S 200 decanter for its CYCLATOR™ basins and directed the commissioning.

  • 630 m³/day
  • 7,627 PE
  • CYCLATOR · BIODEC S 200 ×1
  • Permit and construction design, decanter supply, commissioning management
  • Communal STP
  • Completed 2016.
ClientVeolia Water Technologies
LocationFegyvernek-Örményes, Hungary
SegmentMunicipal
Capacity630 m³/day
TechnologiesCYCLATOR, BIODEC

Parameters as commissioned

Influent, the consent limit, and the effluent quality actually measured.

 
Parameter Influent (mg/l) Effluent Limit (mg/l) Effluent Quality (mg/l)
CODKr 1,476 75 51
BOD5 738 25 14
TN 136 50 2.5
NH4-N 82 10 0.9
TSS 828 50 10
TP 30 5 0.8
 