UTB Envirotec 30-year anniversary logo

Contact

← All case studies

Ózd

Ózd, Hungary

CYCLATORBIODECMETHANATORMunicipal

Scope of supply

UTB prepared the permit and construction design for the Ózd municipal wastewater treatment plant under the KEOP programme, supplied the BIODEC™ S 200 decanters for the CYCLATOR™ basins and directed the commissioning. UTB also designed the plant’s METHANATOR™ sludge digester in 2015. The plant is operated by Borsodvíz.

  • 5,400 m³/day
  • 33,350 PE
  • CYCLATOR · BIODEC S 200 ×8
  • Permit and construction design, decanter supply, commissioning management
  • METHANATOR sludge digester design, 2015
  • Communal STP
  • Completed 2015.
ClientVeolia Water Technologies
LocationÓzd, Hungary
SegmentMunicipal
Capacity5,400 m³/day
TechnologiesCYCLATOR, BIODEC, METHANATOR

Parameters as commissioned

Influent, the consent limit, and the effluent quality actually measured.

Parameter Influent (mg/l) Effluent Limit (mg/l) Effluent Quality (mg/l)
CODKr 1,200 125 50
BOD5 600 25 12
TN 140 55 4
NH4-N 100 20 2
TSS 1,000 35 25
TP 20 10 2.8

On site

Overhead drone view of the CYCLATOR SBR basins and buildings at the Ózd wastewater treatment plant, HungaryAerial view of the Ózd municipal wastewater treatment plant and its CYCLATOR basins in the valley, HungaryNight-time aerial view of the illuminated Ózd wastewater treatment plant, Hungary